![Installation Installation](https://www.gielle.it/wp-content/uploads/2016/02/inergen-ag-k.jpg)
Systems you can depend on to protect lives, property and the environment.
Design, Install & ServiceKoetter Fire Protection will design, install and service your Ansul INTERGEN fire protection system. Our factory trained design experts produce engineered drawings using the latest versions of AutoCAD detailing the expected performance of your Inergen system. Support 24x7 You Can Count On!Koetter Fire's Service Department offers 24-hour emergency service and routine service to keep your Inergen fire system operational at all times. | |
|
INERGEN ALLOWABLE FLOW RATES VS. PIPE ID looooo 100 I 11 I 0 2 4 6 8 PIPE ID (inches) I-MIN RATE -MAX RATE 1 Figure 4 Under normal conditions, the maximum flow in a gas is determined by the sonic velocity for the gas. The maximum flow rate was set to avoid sonic velocity, or choked flow conditions, in the INERGEN system pipe. Double action manual releasing stations shall be provided at each exit of the protected area and shall, when activated, immediately release the INERGEN agent and cause all audible/visual alarms to activate. In addition, activation of the manual releasing stations shall cause immediate shutdown of interconnected electrical circuits. Fire Eater A/S manufactures and supplies INERGEN® systems to a network of distributors and business partners all around the world.
INERGEN agent is composed of three naturally occurring gases found in the air we breathe - nitrogen, argon and a small amount of carbon dioxide, which improves human safety. Fires are suppressed quickly with no residue to clean up. INERGEN agent's ozone depletion level, global warming potential and atmospheric lifetime are all ZERO. Because it is not a synthetic chemical, it has not been banned or restricted for use by any country. It is listed and approved by governmental, nationally and internationally recognized testing laboratories.
Installation
Ansul Inergen clean agent fire suppression systems protect enclosed areas where there is a need for quick reaction to a fire, where people may be present, where fire may strike day or night, and where damage from conventional agents cannot be tolerated.
The Ansul Inergen Fire Suppression System Dlc going east product key. is a pre-engineered, stored pressure with a fixed nozzle distribution network. It is listed with Underwriters Laboratories, Inc. Adobe indesign cs5 me portable free download. (UL). The system is capable of automatic detection and actuation and/or remote manual actuation. Additional accessories are available for shutting down electrical power to equipment and shutting down the flow of gas lines.
The detection portion of the fire suppression system allows for automatic detection by means of specifically rated mechanical fusible links or electric thermal detectors. The fire suppression system has capabilities for total flooding, local application – tankside, and local application – overhead.
Applications That Benefit From Inergen Fire Suppression Systems:
- Automated Tape Storage Libraries
- Computer And Data Processing Facilities
- Cultural And Historical Sites
- Hospital And Major Medical Facilities
- Marine/Offshore/ Naval
- Museums And Art Galleries
- Power Generation Facilities
- Telecommunication Facilities
- Industrial Applications:
- Hazardous Storage Buildings
- Dip Tanks
- Paint Lockers
- Flammable Liquid Storage Facilities
- Stock Rooms
- Printing Machines
- Mixing Tanks
- Electrical Motors
- Pumps
- Switchgear Rooms
- Indoor Transformers
- Wood Finishing Operations
Ansul's INERGEN, The BETTER Solution . . .
INERGEN is Better For Your Property
Upon discharge, INERGEN instantly floods the room, remaining suspended to suppress fires quickly and effectively. Midiquest xl 10.0.5 serial. An inert gas mixture, INERGEN is absolutely free of residues and corrosive by-products that may produce further property damage. In performance testing, INERGEN easily exceeded the NFPA Standard 2001 allowance of one-minute discharge, with documented extinguishments of 22 seconds for a Class A fire and 17 seconds for a Class B fire. Reliable and field proven, INERGEN delivers the performance you would expect from the world leader in fire suppression.
Ansul Inergen Installation Manual
INERGEN is Better For Your People
One of the most remarkable aspects of INERGEN is that it is safe for people. Unlike halocarbon (chemical) alternatives, which can create dangerous levels of hydrogen fluoride when in the presence of fire, INERGEN is entirely nontoxic, producing no corrosive decomposition products whatsoever. Plus, because INERGEN will not produce a fog when discharged, escape routes remain visible.
With INERGEN, the oxygen level is reduced enough to put out the flames, yet more than enough remains to breathe. In fact, those who breathe normally around INERGEN in extinguishing concentrations receive the same amount of oxygen to the brain as they would in an ordinary atmosphere, vital in cases where immediate evacuation may not be possible.
INERGEN is Better For The Environment
The production of Halon 1301 was banned in 1993, a direct result of its negative effects on the ozone layer. We engineered INERGEN to be environmentally kind from the very start. INERGEN is nonsynthetic, made exclusively of gases we already breathe: nitrogen, argon, and carbon dioxide. Once discharged, it simply returns to the atmosphere in its natural state. And because it poses no ozone depletion or global warming potential, INERGEN will never be subject to future legislative bans.
State-Of-The-Art Detection And Control
INERGEN systems combine exclusive AUTOPULSE® microprocessor units with highly sensitive smoke, heat and flame detectors, and specialized agent distribution components, designed to detect and suppress a fire even before it reaches the flame stage. The AUTOPULSE units also perform other key functions in case of fire, including sounding alarms, closing doors, and shutting down equipment. In conjunction with manual pull stations, the system provides automatic detection, day and night.
Flexibility Is Already Built In
INERGEN agent is stored as a gaseous mixture in DOT-approved steel cylinders filled to nominal capacities of 200 to 435 cu. ft. (5.7 to 12.3 cu. m). Available in four sizes, you can choose to install your cylinders either vertically or horizontally, allowing for a design that requires the fewest number of cylinders and the lowest cost. You then have a choice of setting up your cylinders to open electrically, pneumatically or manually, depending on your need.
Installation Guide
EVEN AFTER THE FIRE, YOU'RE UP AND RUNNING
In minutes, fire and the attempts to put it out can destroy the equipment that keeps your operation in action. And yet, without the right defenses in place - those that protect people, property and the environment - many businesses are putting themselves at needless risk every day. Others, however, have an INERGEN® system at the ready.
Created as an ozone-safe replacement for Halon 1301, INERGEN is the nucleus of ANSUL's contemporary approach to fire protection: protect lives, protect property and protect the environment.
Clean, non-conductive INERGEN is a natural fire suppression agent particularly suited to areas where damage from conventional agents cannot be tolerated, such as sensitive data storage, information processing and systems operation electronics. In addition, many archival organizations use INERGEN to protect valuable, irreplaceable items such as artwork, historic documents and antiquities.